    I could add a ,studavent? but I think it will drain fine anyway without the vent. I'm in Ohio and I'm not sure what the code requires on this issue although I suspect it says to vent it even in my case. I am concerned about the siphoning aspect of losing my water seal. The place I'm tapping into the main drain is fairly close,7', from where the waste stack leaves the house.

    I am installing a new washer hookup in a first floor room.(moving it from the basement).I was going to run a 2" standpipe from the washer to the main drain in the basement which is only 4' away from where I will go through the floor with the drain. Do I put the trap in the riser or close to the main drain tie in. And do I need to vent it other than the venting it will get from the main stack vent. If I have to vent it I may have to use a studavent since my main stack vent is hard to get to and cut into in the attic.(which is the only place it is exposed).
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Feb 1, 2010, 06:50 AM
    Hi Jhopfd...

    You want to install the trap and the vent pretty close to each other... see image below.

    Pitch the drain pipe at 1/4" per foot of pipe and hang the pipe every 4 feet.

    Be sure to install a 2" cleanout in the drain pipe as well... code required and darn handy to have when you need it in the future!

    Back to you...

    MARK
    Attached Images
     
    jhopfd's Avatar
    jhopfd Posts: 4, Reputation: 1
    New Member
     
    #3

    Feb 2, 2010, 11:44 AM

    Thanks for the input. I was hoping to get away without the aav but I figured I would have to install one since all the rest of the waste from all other sources in the house are above the point where I will be tying in to the main stack. Is the aav a product that can be relied on for along time, If I need to I will take the vent up a chase shaft from the basement to the attic and out the roof but it's winter here right now and I'd rather not cut the hole through the roof and try to seal it now.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Feb 2, 2010, 06:02 PM
    I am a big fan of installing vents without mechanical parts, but AAVs are considered very reliable, however, they can fail. Code requires that they are accessible via putting the AAV under the cabinet or installing an access panel.

    You definitely need to add a vent somehow... ;)

    Back to you...

    MARK
    jhopfd's Avatar
    jhopfd Posts: 4, Reputation: 1
    New Member
     
    #5

    Feb 3, 2010, 04:23 PM

    Thanks again. I was intending on going through the floor to my basement with a straight 2" from my washing machine hookup box, then putting the trap/w/cleanout in the basement where I came through the floor and then going appox. 4' horizontally with the fall you suggested to a sweep 90 and into my main 3" waste stack. If I put a t where I tie into my waste stack and install an aav there is that close enough to work. I'll be running the horizontal section close to the ceiling in the basement since my main stack runs essentially horizontal/slight slope only 18" from the basement ceiling. It exits the house about halfway up the basement wall. There is already a 3" cleanout a few ' before where I am tying in. That would allow me to hug the basement ceiling until I get to the main. Otherwise I will have to install my trap lower in the basement to give me enough room to install the aav immediately after the trap. I'm trying to avoid using up headroom where my 2" comes down into the basement since it's a little more out into the middle of the basement room compared to where the main drain is (against a wall).
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #6

    Feb 3, 2010, 05:33 PM
    The trap doesn't belong in the basement. Install the PTRAP above the floor. The AAV can also go in the wall... you'll need an access panel for that. Home depot sells a great spring loaded access panel... can be painted or wall-papered.

    Mark
    Attached Images
      
    jhopfd's Avatar
    jhopfd Posts: 4, Reputation: 1
    New Member
     
    #7

    Feb 4, 2010, 08:56 AM

    OK, Thank You!
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #8

    Feb 4, 2010, 05:46 PM
    Glad to help!

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Installing a floating floor over existing parquet floor [ 4 Answers ]

I live in a condo and currently have 8" square oak parquet floors. The parquet is half an inch thick and glued down to the concrete subfloor (it is glued with a think black substance that I was told is tar). The flooring has been in the building for nearly 50 years and seems to be well intact...

Basement washer drain connection to existing floor drain [ 10 Answers ]

I am on city service. I would like to connect my basement washer drain into the existing floor drain (3" line). I cut the line about 3 feet down from floor trap and installed a 3x2inch y. This existing floor drain takes a 45 turn about 6" down from where I cut it. The 2 inch will drain the washer ....

Electric main hookup [ 2 Answers ]

I have overhead electric service 150 ft to a pole with a meter then another 150 ft underground to the house. I have now built a garage near the meter pole. I want to transfer the meter to the transformer pole and bury the overhead , comeing up at the garage and then split it to the garage and the...

Installing Floor Drain in Existing Basement [ 4 Answers ]

I would like to install a floor drain in an existing basement to drain my high efficiency furnace, my air conditioner coil, and my hot water heater (to clean it). About 10 feet from my proposed location I have a vertical 2" ABS pipe along the wall draining upstairs sink and dishwasher. This pipe...

Moving washer to 2nd floor? How to connect to existing shower drain? [ 1 Answers ]

Hello, I would like to move my laundry area to the 2nd floor. I have an existing water connection and drain I like to use. I got a hefty estimate from a plumber and while I am an amateur, I'd like to see how it is done. Our plan included installing a pump/reservior that would eliminate...


View more questions Search